Electron beam welding The stability and reliability of the ion source are crucial for the long-term stable operation of the mass spectrometer, a stable ion source can continuously produce a stable ion beam, ensure the reproducibility and accuracy of the mass spectrometer, provide reliable data support for scientific research and practical applications, so the precision processing of ion source parts is very important.

Electron beam welding  

According to the design requirements of the ion source components, choose suitable stainless steel materials, such as 304, 316 stainless steel, etc. These stainless steel materials have good corrosion resistance and mechanical properties, which can meet the needs of ion source components working in complex environments.

According to the design requirements of the ion source components, choose suitable stainless steel materials, such as 304, 316 stainless steel, etc. These stainless steel materials have good corrosion resistance and mechanical properties, which can meet the needs of ion source components working in complex environments.

    oops...!

    no product data.

    Go to homepage

    Efficient, Durable, Customizable Design 

    The ion source is the core component of the mass spectrometer, which plays a crucial role in the performance and analysis results of the mass spectrometer, and the performance of the ion source directly affects the ionization efficiency, which in turn largely determines the sensitivity of the mass spectrometer.

    1e6922275870f2986ff9de3789c3083(1)
    cc27506511fb1a5fba7c2334e0a1bf6(1)

    Influence mass spectral information richness

    Different ion sources will cause different degrees of fragmentation of sample molecules, thus providing different types of mass spectral data. For example, EI can provide abundant structural information and fragment ion peaks of organic compounds, but it is not suitable for samples with difficult volatilization and poor thermal stability against short circuit. Chemical ionization (CI) usually obtains quasimolecular ions, which can be used to analyze thermally unstable or volatile compounds, providing relatively simple mass spectrometry and helping to determine the molecular weight of the compound, so the processing of the ion source parts will be very rigorous.

    Ensuring the overall performance of the mass spectrometer

    The stability and reliability of the ion source are crucial for the long-term stable operation of the mass spectrometer, so our processing accuracy and surface finish requirements are very high, only a stable ion source can continuously produce a stable ion beam, ensure the reproducibility and accuracy of the mass spectrometer, and provide reliable data support for scientific research and practical applications.


    ◎ Reliable 

    ◎ Stable

    ◎ lasting

    e90c032fff958d2081ecc5c03ed0347(1)

    FAQ

    1
    What if the ion source electrode processing accuracy does not meet the standard?
    The accuracy and parameter settings of the machining equipment need to be checked. It could be a weary tool or improper cutting parameters. Re-calibrate equipment, replace tools, and optimize parameters to improve electrode machining accuracy.
    2
    Poor surface roughness in ionic source cavity processing?
    The reason is often a faulty machining process or tool selection. You can try to use more sophisticated machining techniques, such as polishing, grinding, etc., and choose the right tool to ensure smooth surface of the cavity.
    3
    What happens to deformation when the ion source gate is processed?
    The gate material is thin and easily deformed. In machining, it is necessary to optimize the packing method and control the cutting force and temperature. Use special clamps to lower cutting parameters or increase auxiliary support to prevent deformation.
    4
    The processing dimensions of the ion source components are too large?
    It may be that the design drawings are misinterpreted or the machining process is incorrectly located. Careful checking of blueprints, use of high accuracy gauges, improvement of positioning jigs and method of measurement is required to correct deviations.
    5
    The ion source coil circumference does not affect the performance very closely?
    Imbalanced tension during circumference and improper operation will cause the coils to be untight. The coil tension should be controlled, and professional coil equipment and processes should be used to ensure that the coil is tightly circled to ensure electromagnetic performance.
    Get in touch with us
    Just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs
    Related Products
    no data
    Contact person: Mr. Mew
    Tel: 86-010-64386101
    WhatsApp: 86 16046263015
    Company address: #10 Ge Daizi Middle Street, Lisui Town, Shunyi District, Beijing China
    Customer service
    detect